New Multiplex Assay Kit for Major Histocompatibility Complex Class I G (MHCG) ,etc. by FLIA (Flow Luminescence Immunoassay) View larger

Multiplex Assay Kit for Major Histocompatibility Complex Class I G (MHCG) ,etc. by FLIA (Flow Luminescence Immunoassay)

CC-LMB856Hu

New product

HLA-G; MHC-G; HLAG; Leukocyte Antigen G; b2 microglobulin; HLA class I histocompatibility antigen, alpha chain G

More details

Registe-se for viewing this price!

Ao comprar este produto pode ganhar até 8 pontos de fidelização. Seu carrinho totalizará 8 pontos de fidelização que podem ser convertidos num vale de desconto de 32.00EUR.


Data sheet

Applications FLIA Kit for Antigen Detection.
Detection Range 0.02-24ng/mL
Sensitivity The minimum detectable dose of this kit is typically less than 0.007 ng/mL
Specificity <p>
Research Area Apoptosis
Organism species Homo sapiens (Human)
Alternative Names HLA-G
Item Name Major Histocompatibility Complex Class I G
Assay Length 3h
Method Double-antibody Sandwich
Sample Type Serum, plasma, tissue homogenates and other biological fluids
Formato 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Test Principle Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinyla
Assay procedure summary 1. Preparation of standards, reagents and samples before the experiment
UniProt ID P17693

More info

Especificidad:

This assay has high sensitivity and excellent specificity for detection of Major Histocompatibility Complex Class I G (MHCG) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Major Histocompatibility Complex Class I G (MHCG) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Click here for manual in PDF

Click here for OD image