New ELISA Kit for TNF Receptor Associated Factor 3 (TRAF3) View larger

ELISA Kit for TNF Receptor Associated Factor 3 (TRAF3)

CC-SEG753Hu

New product

48T, 96T, 96T×5, 96T×10, 96T×100

More details

Registe-se for viewing this price!

Ao comprar este produto pode ganhar até 7 pontos de fidelização. Seu carrinho totalizará 7 pontos de fidelização que podem ser convertidos num vale de desconto de 28.00EUR.


Data sheet

Size 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Applications Enzyme-linked immunosorbent assay for Antigen Detection.
Detection Range 15.6-1,000pg/mL
Sensitivity The minimum detectable dose of this kit is typically less than 5.5pg/mL
Research Area Tumor immunity
Organism species Homo sapiens (Human)
Alternative Names LAP1
Item Name TNF Receptor Associated Factor 3
Assay Length 3h
Method Double-antibody Sandwich
Sample Type serum, plasma, tissue homogenates, cell lysates and other biological fluids
Test Principle The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to TNF Receptor Associated Factor 3 (TRAF3). Standards or samples are then added to the appropri
Assay procedure summary 1. Prepare all reagents, samples and standards
UniProt ID Q13114

More info

Especificidad:

This assay has high sensitivity and excellent specificity for detection of TNF Receptor Associated Factor 3 (TRAF3).
No significant cross-reactivity or interference between TNF Receptor Associated Factor 3 (TRAF3) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level TNF Receptor Associated Factor 3 (TRAF3) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level TNF Receptor Associated Factor 3 (TRAF3) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Estabilidad:

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Click here for manual in PDF

Click here for OD image