CC-SEB973Ra
New product
This product is no longer in stock
Availability date:
Ao comprar este produto pode ganhar até 7 pontos de fidelização. Seu carrinho totalizará 7 pontos de fidelização que podem ser convertidos num vale de desconto de 28.00EUR.
Size | 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100 |
Storage Conditions | -20°C |
Shipping Conditions | Entre 4°C y 8°C |
Applications | Enzyme-linked immunosorbent assay for Antigen Detection. |
Detection Range | 78.12-5000pg/mL |
Sensitivity | The minimum detectable dose of this kit is typically less than 30.5pg/mL |
Research Area | Enzyme & Kinase |
Organism species | Rattus norvegicus (Rat) |
Alternative Names | C3-C5 |
Item Name | A Disintegrin And Metalloproteinase With Thrombospondin 1 |
Assay Length | 3h |
Method | Double-antibody Sandwich |
Sample Type | Serum, plasma, tissue homogenates and other biological fluids. |
Formato | 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100 |
Test Principle | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to A Disintegrin And Metalloproteinase With Thrombospondin 1 (ADAMTS1). Standards or samples are |
Assay procedure summary | 1. Prepare all reagents, samples and standards |
UniProt ID | Q9WUQ1 |
This assay has high sensitivity and excellent specificity for detection of A Disintegrin And Metalloproteinase With Thrombospondin 1 (ADAMTS1).
No significant cross-reactivity or interference between A Disintegrin And Metalloproteinase With Thrombospondin 1 (ADAMTS1) and analogues was observed.
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level A Disintegrin And Metalloproteinase With Thrombospondin 1 (ADAMTS1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level A Disintegrin And Metalloproteinase With Thrombospondin 1 (ADAMTS1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.