CLIA Kit for Interleukin 34 (IL34) View larger

CLIA Kit for Interleukin 34 (IL34)

CC-SCC007Hu

New product

48T, 96T, 96T×5, 96T×10, 96T×100

More details

Registe-se for viewing this price!

Ao comprar este produto pode ganhar até 8 pontos de fidelização. Seu carrinho totalizará 8 pontos de fidelização que podem ser convertidos num vale de desconto de 32.00EUR.


Data sheet

Size 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Storage Conditions -20°C
Shipping Conditions Entre 4°C y 8°C
Applications Chemiluminescent immunoassay for Antigen Detection.
Detection Range 1.37-1,000pg/mL
Sensitivity The minimum detectable dose of this kit is typically less than 0.49pg/mL
Research Area Cytokine
Organism species Homo sapiens (Human)
Alternative Names C16orf77
Item Name Interleukin 34
Assay Length 2h, 40min
Method Double-antibody Sandwich
Sample Type serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Formato 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Test Principle The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 34 (IL34). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 34 (IL34). Next,
Assay procedure summary 1. Prepare all reagents, samples and standards
UniProt ID Q6ZMJ4

More info

Especificidad:

This assay has high sensitivity and excellent specificity for detection of Interleukin 34 (IL34).
No significant cross-reactivity or interference between Interleukin 34 (IL34) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 34 (IL34) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 34 (IL34) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Estabilidad:

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Click here for manual in PDF

Click here for OD image