CLIA Kit for Secretory Leukocyte Peptidase Inhibitor (SLPI) View larger

CLIA Kit for Secretory Leukocyte Peptidase Inhibitor (SLPI)

CC-SCB312Mu

New product

48T, 96T, 96T×5, 96T×10, 96T×100

More details

Registe-se for viewing this price!

Ao comprar este produto pode ganhar até 8 pontos de fidelização. Seu carrinho totalizará 8 pontos de fidelização que podem ser convertidos num vale de desconto de 32.00EUR.


Data sheet

Size 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Storage Conditions -20°C
Shipping Conditions Entre 4°C y 8°C
Applications Chemiluminescent immunoassay for Antigen Detection.
Detection Range 1.37-1,000pg/mL
Sensitivity The minimum detectable dose of this kit is typically less than 0.64pg/mL
Research Area Immune molecule
Organism species Mus musculus (Mouse)
Alternative Names ALK1
Item Name Secretory Leukocyte Peptidase Inhibitor
Assay Length 2h, 40min
Method Double-antibody Sandwich
Sample Type Serum, plasma and other biological fluids
Formato 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Test Principle The microplate provided in this kit has been pre-coated with an antibody specific to Secretory Leukocyte Peptidase Inhibitor (SLPI). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Secr
Assay procedure summary 1. Prepare all reagents, samples and standards
UniProt ID P97430

More info

Especificidad:

This assay has high sensitivity and excellent specificity for detection of Secretory Leukocyte Peptidase Inhibitor (SLPI).
No significant cross-reactivity or interference between Secretory Leukocyte Peptidase Inhibitor (SLPI) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Secretory Leukocyte Peptidase Inhibitor (SLPI) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Secretory Leukocyte Peptidase Inhibitor (SLPI) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Estabilidad:

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Click here for manual in PDF

Click here for OD image