CLIA Kit for 8-Hydroxydeoxyguanosine (8-OHdG) View larger

CLIA Kit for 8-Hydroxydeoxyguanosine (8-OHdG)

CC-CCA660Ge

New product

48T, 96T, 96T×5, 96T×10, 96T×100

More details

Registe-se for viewing this price!

Ao comprar este produto pode ganhar até 10 pontos de fidelização. Seu carrinho totalizará 10 pontos de fidelização que podem ser convertidos num vale de desconto de 40.00EUR.


Data sheet

Size 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Storage Conditions -20°C
Shipping Conditions Entre 4°C y 8°C
Applications Chemiluminescent immunoassay for Antigen Detection.
Detection Range 23.44-6,000pg/mL
Sensitivity The minimum detectable dose of this kit is typically less than 7.97pg/mL
Research Area Metabolic pathway
Organism species Pan-species (General)
Alternative Names 8OHdG
Item Name 8-Hydroxydeoxyguanosine
Assay Length 2h
Method Competitive Inhibition
Sample Type serum, plasma and other biological fluids
Formato 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Test Principle The microplate provided in this kit has been pre-coated with an antibody specific to 8-OHdG analogues. Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to 8-OHdG analogues. Next, Avidin con
Assay procedure summary 1. Prepare all reagents, samples and standards
UniProt ID -

More info

Especificidad:

This assay has high sensitivity and excellent specificity for detection of 8-Hydroxydeoxyguanosine (8-OHdG).
No significant cross-reactivity or interference between 8-Hydroxydeoxyguanosine (8-OHdG) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level 8-Hydroxydeoxyguanosine (8-OHdG) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level 8-Hydroxydeoxyguanosine (8-OHdG) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Estabilidad:

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Click here for manual in PDF

Click here for OD image