CLIA Kit for Glycated Hemoglobin A1c (HbA1c) View larger

CLIA Kit for Glycated Hemoglobin A1c (HbA1c)

CC-CCA190Hu

New product

48T, 96T, 96T×5, 96T×10, 96T×100

More details

Registe-se for viewing this price!

Ao comprar este produto pode ganhar até 7 pontos de fidelização. Seu carrinho totalizará 7 pontos de fidelização que podem ser convertidos num vale de desconto de 28.00EUR.


Data sheet

Size 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Storage Conditions -20°C
Shipping Conditions Entre 4°C y 8°C
Applications Chemiluminescent immunoassay for Antigen Detection.
Detection Range 5.86-1,500μg/mL
Sensitivity The minimum detectable dose of this kit is typically less than 2.44μg/mL
Organism species Homo sapiens (Human)
Alternative Names Glycosylated Hemoglobin
Item Name Glycated Hemoglobin A1c
Assay Length 2h
Method Competitive Inhibition
Sample Type serum, plasma and erythrocyte lysates
Formato 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Test Principle The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Glycated Hemoglobin A1c (HbA1c). A competitive inhibition reaction is launched between biotin labeled Glycated Hemoglobin A1c (HbA1c) and unlabeled Glycated Hem
Assay procedure summary 1. Prepare all reagents, samples and standards
UniProt ID O95602

More info

Especificidad:

This assay has high sensitivity and excellent specificity for detection of Glycated Hemoglobin A1c (HbA1c).
No significant cross-reactivity or interference between Glycated Hemoglobin A1c (HbA1c) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glycated Hemoglobin A1c (HbA1c) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glycated Hemoglobin A1c (HbA1c) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Estabilidad:

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Click here for manual in PDF

Click here for OD image