ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL) Ver mas grande

ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

CC-CEA527Rb

Producto nuevo

48T, 96T, 96T×5, 96T×10, 96T×100

Más detalles

Por favor regístrese para ver el precio

Comprando este producto generará 6 Biopuntos. Su cesta contiene un total 6 Biopuntos puede ser convertido en un Biobonos Descuento 24.00EUR.


Añadir a Mis Favoritos

Hoja técnica

Size 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Applications Enzyme-linked immunosorbent assay for Antigen Detection.
Detection Range 12.35-1,000ng/mL
Sensitivity The minimum detectable dose of this kit is typically less than 4.34ng/mL
Research Area Metabolic pathway
Organism species Oryctolagus cuniculus (Rabbit)
Alternative Names OL
Item Name Oxidized Low Density Lipoprotein
Assay Length 2h
Method Competitive Inhibition
Sample Type serum, plasma and other biological fluids
Formato 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Test Principle This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Oxidized Low Density Lipoprotein (OxLDL) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labe
Assay procedure summary 1. Prepare all reagents, samples and standards
UniProt ID -

Más información

Especificidad:

This assay has high sensitivity and excellent specificity for detection of Oxidized Low Density Lipoprotein (OxLDL).
No significant cross-reactivity or interference between Oxidized Low Density Lipoprotein (OxLDL) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Oxidized Low Density Lipoprotein (OxLDL) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Oxidized Low Density Lipoprotein (OxLDL) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Estabilidad:

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Click here for manual in PDF

Click here for OD image