CLIA Kit for Amyloid Precursor Protein (APP) Ver mas grande

CLIA Kit for Amyloid Precursor Protein (APP)

CC-SCB020Hu

Producto nuevo

48T, 96T, 96T×5, 96T×10, 96T×100

Más detalles

Por favor regístrese para ver el precio

Comprando este producto generará 8 Biopuntos. Su cesta contiene un total 8 Biopuntos puede ser convertido en un Biobonos Descuento 32.00EUR.


Añadir a Mis Favoritos

Hoja técnica

Size 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Storage Conditions -20°C
Shipping Conditions Entre 4°C y 8°C
Applications Chemiluminescent immunoassay for Antigen Detection.
Detection Range 6.86-5,000pg/mL
Sensitivity The minimum detectable dose of this kit is typically less than 2.43pg/mL
Research Area Neuro science
Organism species Homo sapiens (Human)
Alternative Names AAA
Item Name Amyloid Precursor Protein
Assay Length 2h, 40min
Method Double-antibody Sandwich
Sample Type Serum, plasma, cerebrospinal fluid and other biological fluids
Formato 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Test Principle The microplate provided in this kit has been pre-coated with an antibody specific to Amyloid Precursor Protein (APP). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Amyloid Precursor P
Assay procedure summary 1. Prepare all reagents, samples and standards
UniProt ID P05067

Más información

Especificidad:

This assay has high sensitivity and excellent specificity for detection of Amyloid Precursor Protein (APP).
No significant cross-reactivity or interference between Amyloid Precursor Protein (APP) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Amyloid Precursor Protein (APP) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Amyloid Precursor Protein (APP) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Estabilidad:

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Click here for manual in PDF

Click here for OD image