CLIA Kit for Insulin Like Growth Factor 1 (IGF1) Ver mas grande

CLIA Kit for Insulin Like Growth Factor 1 (IGF1)

CC-SCA050Bo

Producto nuevo

48T, 96T, 96T×5, 96T×10, 96T×100

Más detalles

Por favor regístrese para ver el precio

Comprando este producto generará 10 Biopuntos. Su cesta contiene un total 10 Biopuntos puede ser convertido en un Biobonos Descuento 40.00EUR.


Añadir a Mis Favoritos

Hoja técnica

Size 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Storage Conditions -20°C
Shipping Conditions Entre 4°C y 8°C
Applications Chemiluminescent immunoassay for Antigen Detection.
Detection Range 27.4-20,000pg/mL
Sensitivity The minimum detectable dose of this kit is typically less than 10.7pg/mL
Research Area Tumor immunity
Organism species Bos taurus
Alternative Names IGFI
Item Name Insulin Like Growth Factor 1
Assay Length 2h, 40min
Method Double-antibody Sandwich
Sample Type Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Formato 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Test Principle The microplate provided in this kit has been pre-coated with an antibody specific to Insulin Like Growth Factor 1 (IGF1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Insulin Like Gr
Assay procedure summary 1. Prepare all reagents, samples and standards
UniProt ID P07455

Más información

Especificidad:

This assay has high sensitivity and excellent specificity for detection of Insulin Like Growth Factor 1 (IGF1).
No significant cross-reactivity or interference between Insulin Like Growth Factor 1 (IGF1) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Insulin Like Growth Factor 1 (IGF1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Insulin Like Growth Factor 1 (IGF1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Estabilidad:

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Click here for manual in PDF

Click here for OD image