CLIA Kit for Antidiuretic Hormone (ADH) Ver mas grande

CLIA Kit for Antidiuretic Hormone (ADH)

CC-CCB139Mu

Producto nuevo

48T, 96T, 96T×5, 96T×10, 96T×100

Más detalles

Por favor regístrese para ver el precio

Comprando este producto generará 8 Biopuntos. Su cesta contiene un total 8 Biopuntos puede ser convertido en un Biobonos Descuento 32.00EUR.


Añadir a Mis Favoritos

Hoja técnica

Size 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Storage Conditions -20°C
Shipping Conditions Entre 4°C y 8°C
Applications Chemiluminescent immunoassay for Antigen Detection.
Detection Range 11.72-3,000pg/mL
Sensitivity The minimum detectable dose of this kit is typically less than 4.28pg/mL
Research Area Signal transduction
Organism species Mus musculus (Mouse)
Alternative Names ARVP
Item Name Antidiuretic Hormone
Assay Length 2h
Method Competitive Inhibition
Sample Type Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Formato 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Test Principle The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Antidiuretic Hormone (ADH). A competitive inhibition reaction is launched between biotin labeled Antidiuretic Hormone (ADH) and unlabeled Antidiuretic Hormone (
Assay procedure summary 1. Prepare all reagents, samples and standards
UniProt ID P35455

Más información

Especificidad:

This assay has high sensitivity and excellent specificity for detection of Antidiuretic Hormone (ADH).
No significant cross-reactivity or interference between Antidiuretic Hormone (ADH) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Antidiuretic Hormone (ADH) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Antidiuretic Hormone (ADH) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Estabilidad:

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.