Instant ELISA Kit for Indole 3 Acetic Acid (IAA) Ver mas grande

Instant ELISA Kit for Indole 3 Acetic Acid (IAA)

CC-IEA737Ge

Producto nuevo

48T, 96T, 96T×5, 96T×10, 96T×100

Más detalles

Por favor regístrese para ver el precio

Comprando este producto generará 9 Biopuntos. Su cesta contiene un total 9 Biopuntos puede ser convertido en un Biobonos Descuento 36.00EUR.


Añadir a Mis Favoritos

Hoja técnica

Size 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Storage Conditions -20°C
Shipping Conditions Entre 4°C y 8°C
Applications Enzyme-linked immunosorbent assay for Antigen Detection.
Detection Range 320-200,000pg/mL
Sensitivity The minimum detectable dose of this kit is typically less than 109pg/mL
Research Area Signal transduction
Organism species Pan-species (General)
Alternative Names IA-A
Item Name Indole 3 Acetic Acid
Assay Length 1h, 10min
Method Competitive Inhibition
Sample Type tissue or cell culture supernates
Formato 48T, <i>96T</i>, 96T×5, 96T×10, 96T×100
Test Principle This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Instant Indole 3 Acetic Acid (IAA) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled In
Assay procedure summary 1. Prepare all reagents, samples and standards
UniProt ID -

Más información

Especificidad:

This assay has high sensitivity and excellent specificity for detection of Instant Indole 3 Acetic Acid (IAA).
No significant cross-reactivity or interference between Instant Indole 3 Acetic Acid (IAA) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Instant Indole 3 Acetic Acid (IAA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Instant Indole 3 Acetic Acid (IAA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Estabilidad:

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.